EEW ZXF8575 Explosion Proof Corrosion Resistance Plug And Receptacles (IIC, TD)

Application

Designed for explosive atmospheres Zone 1 and Zone 2; Designed for combustible dust Zone 21 and Zone 22; Designed for IIA, IIB and IIC groups explosive atmospheres; Designed for temperature classifications T1~T6; Designed for explosive hazardous locations such as oil refinery, storage, chemical, pharmaceuticals, militaryindustries etc.; It is composed of plug and receptacle

Certified Authentic With Complete Certificate

SKU: EP-047-12 Categories: ,

Description

Model Code

Ordering References

Connector is used for distant connection of cables. Current is only of 16A; For example: If need explosion proof corrosion resistant plug and receptacles, with rated voltage 220V, rated current 16A, the model shall be “ZXF8575-16/220”.

Features

Enclosure is made from GRP with good appearance and heat stability, and it has the features of good shape, corrosion resistance, static resistance, impact resistance, good thermal reliability, etc . With interlock device, plug can be pulled out only after switch cut off inside the socket; If out of operation, the lid can’t be opened by the locking of designed on receptacles; Steel pipe or cable wiring.

Technical Parameters

ZXF8575-16

Selection Table

Technical Parameters of ZXF8575-16

Compliance with: GB 3836.1, GB 3836.2, GB 3836.3, GB 12476.1, GB12476.5, IEC60079-0, IEC60079-1, IEC60079-7, IEC 61241-0, IEC 61241-1; Explosion protection: Ex d e II CT6 Gb, Ex tD A21 IP66 T80℃; Rated voltage: AC380, AC220, AC110, DC36, DC24; Poles: 1P+N+PE, 2P, 2P+PE, 3P+N+PE; Rated current: 16A; Ingress protection: IP66; Corrosion resistance: WF2; Cable entry: G3/4″; Cable outer diameters: Φ9mm~Φ14mm.

Outline and Mounting Dimensions of ZXF8575-16

 

ZXF8575-32

Selection Table

Technical Parameters of ZXF8575-32

Compliance with: GB 3836.1, GB 3836.2, GB 3836.3, GB 12476.1, IEC60079-0, IEC60079-1, IEC60079-7, IEC 61241-0, IEC 61241-1; Explosion protection: Ex d e IICT6 Gb, Ex tD A21 IP66 T80℃; Rated voltage: AC380, AC220, AC110, DC36, DC24; Poles: 1P+N+PE, 2P, 2P+PE, 3P+N+PE; Rated current: 32A; Ingress protection: IP66; Corrosion resistance: WF2; Cable entry: G1″; Cable outer diameters: Φ11mm~Φ18mm.

Outline and Mounting Dimensions of ZXF8575-32

 

 ZXF8575-125

Selection Table

Technical Parameters of ZXF8575-125

Compliance with: GB 3836.1, GB 3836.2, GB 3836.3, GB 12476.1, GB12476.5, IEC60079-0, IEC60079-1, IEC60079-7, IEC 61241-0, IEC 61241-1; Explosion protection: Ex d e II CT6 Gb, Ex tD A21 IP66 T80℃; Rated voltage: AC380, AC220, AC415,AC660,AC415690 Poles:3P+PE, 3P+N+PE; Rated current: 62A,100A,125A Ingress protection: IP66; Corrosion resistance: WF2; Cable entry: G3/4″; Cable outer diameters: Φ27mm~Φ49mm.

Outline and Mounting Dimensions of ZXF8575-125

 

ZXF8575-16/□L

Selection Table

ZXF8575-16/□L Technical Parameters

Compliance with: GB 3836.1, GB 3836.2, GB 3836.3, GB 12476.1, GB12476.5, IEC60079-0, IEC60079-1, IEC60079-7, IEC 61241-0, IEC 61241-1; Explosion protection: Ex d e IICT6 Gb, Ex tD A21 IP66 T80℃; Rated voltage: AC380, AC220; Poles: 1P+N+PE, 3P+N+PE; Rated current: 16A; Ingress protection: IP66; Corrosion resistance: WF2; Cable entries: G3/4″, G1″; Cable outer diameters:Φ9mm~Φ14mm, Φ11mm~Φ18mm.

Outline and Mounting Dimensions of ZXF8575-16/□L